Logo Loading

X-ray Control-X Perform-X

รายละเอียดเพิ่มเติม

Control-X Perform-X Classic

Perform-X Classic

Perform-X Classic Digital Radiography System
Performance, Flexibility, Safety and Affordability.

Per form X CLassic has a broad range of feature options as well as digital panels, X-ray tubes, collimators, other components and accessories enable our customers to design customized rad rooms to meet their imaging needs. Our advanced system integration and image acquisition software solutions ensure easy and uncomplicated workflow even in busy hospital environments.

 

  • Thousands of installations prove that the construction of the Perform-X Classic withstands the rigors of the heaviest of caseloads. It offers performance, quality and durability in a modern X-ray suite at a favorable price, featuring:
  • • Hospital-grade components in a single, fully integrated system;
    • free-standing construction with optional rotating tube column, transverse X-ray tube travel and extended longitudinal X-ray tube movement;
    • option of durable elevating or fixed height radiographic table (or Chest/Chiro configuration, without table);
    • Totally redesigned ergonomic membrane console with easily accessible control buttons and digital display for trouble-free beam positioning and exposure preparation;
    • Wide operating range of high-frequency generators for all applications, worldwide;
    • Integrated anatomical programmes (APR) for quick and easy generator parameter set-up;
    • Digital system with wide selection of high resolution and high DQE DR Panels and state-of-the-art Acquisition System for superior image quality and quick diagnoses;
    • low-dose exposures guaranteed by all system components such as generator, Imaging modality and other peripherals such as Automatic Exposure Control (AEC) and Dose Area Product (DAP) meter.

Spectifications:

Tube and wall stand
Vertical travel of x-ray tube (beam center): 35 cm – 185 cm / 14″ – 73″
Vertical travel of wall receptor (centerline): 38 cm – 187 cm / 15″ – 73 2/3″
Longitudinal travel of tube: 180 cm / 71″ (with 247 cm / 97 1/4″ rails), 290 cm / 114 1/4″ (with 360 cm / 141 3/4″ rails)
Fixed grid (optional bucky): 80 l/cm / 200 l/In, 10:1 ratio (other grids also available)
Radiographic Table (Phoenix 1 (Elevating) / Stylix (Fixed Height) High Frequency Generator
Tabletop size: 220 cm x 81 cm (86” x 32”) optional 185 cm / 73” length Output Power: 32, 40 or 50 kW
Longitudinal travel: 110 cm / 43” mA Range: 10-630 mA
Transverse travel: ±12 cm / 4 3/4” (optionally ±14 cm / 5 1/2”) kVp Range: 40-150 kV
Vertical travel range (Phoenix 1): 55 cm – 85 cm / 21 2/3” – 33 1/2” Stored energy generators are available up to 50 kW power
X-Ray Tube Collimator
300 khU 0.6-1.2 mm focal spots (other tubes available) Manual, laser guided LED collimator
Digital Detectors
Detector options: 43×43 cm / 17”x17” or 35×43 cm / 14”x17” fixed or wireless panels with various resolutions available
Integrated Generator Control and Image Acquisition
• Single console seamless workflow
• Full DICoM compatibility
• optional integrated DAP reporting
• Sophisticated image processing features
• grid suppression or gridless imaging
• Detector status indicators
• optional Mini PACS is available
System Footprint Power Requirements (System)
Space requirement: 8 m2; 2.5 m x 3.2 m (86.1 sq. ft.; 8.2′ x 10.5′) with 247 cm (97 1/4″) rails, without generator
12.5 m2; 2.5 x 5 m (134.5 sq. ft.; 8.2′ x 16.4′) with 360 cm (141 3/4″) rails, without generator
Input Line Voltage:
(your input line voltage may limit the generator power)
1x230V or 1x110V (15A) for stored energy generators
3x230V / 3x400V for three-phase generators
Ceiling height requirement: 245 cm / 96 1/2″