เครื่องให้สารละลายทางหลอดเลือดดำ Beyond Semi-2
รายละเอียดเพิ่มเติม
Beyond Semi-2 : Intelligent safety with well-designed and fully functional options.
Features
Auto-Lock Screen : Up to 11 levels time setting; Prevention for operation errors.
Dual CPU : Guarantee for safe work.
Human Voice Alarm : Exclusive technology;
Combination of human voice, readable words and visual light alarm; 8 volume levels are available.
History Record Cassette : Up to 2000pcs records, including operation, alarm and modification; Trackable treatments are ensured.
Night Mode : Design for nighttime safe operation.
System Self-test : System self-test is conducted every time turning on, including alarm indicator, volume, pressure, air bubbles, etc.; Safeguard for every -time use.
WLAN Function : Capable of communicating with information management system; Remotely monitor patient’s condition in real time.
Certification : Certified by TUV Rheinland and EN ISO13485 : 2016
Beyond Semi-2 Technical Data
Applicable Infusion Set | 1ml/15d, 1ml/19d, 1ml/20d, 1ml/60d |
Infusion Rate | ml/h mode : 0.1-2000ml/h drop/min mode : 1- (400ml/h*d/60) d/min |
Unit Conversion | Conversion between drop/min and ml/h |
Bolus Rate & VTBI (Volume to be infused) | Bolus rate : 0.1-1500ml/h VTBI : 0.1-50ml |
FF Rate | FF rate : 0.1-2000ml/h VTBI : 0.1-9999.99ml |
KVO Rate & Volume | KVO rate : 0.1-5ml/h VTBI : 0.1-1ml |
VTBI | 0.1-9999.99ml |
Cumulative Infusion Volume | 0.1-9999.99ml |
Rate Accuracy | Rate over 1ml/h : +-3% (After calibration) Rate under 1ml/h : +-5% (After calibration) |
Occlusion Pressure Level | 13 Levels are available |
Air Bubble Size | 6 levels (25, 50, 100, 250, 500, 800) |
Alarm Information | Near infusion finished, infusion finished, standby task finished, up occlusion, down occlusion, door open, air bubble, forgotten operation, battery low, battery empty, abnormal running state, equipment failure, power fault, unmatched infusion set, replace infusion set, drop sensor is pulled out, empty bottle etc. |
Prompts | Parameter overrun, infusion start, AC power has been pulled out, speed overrun, installation error, maintenance cycle |
Power Source | Three options for power supply: First: 100-240VAC, 50/60Hz Second: Inserted Li-battery 11.1V, capacity more than 2600mAh, after battery is fully charged, it can be used for infusion pump to work continuously for more than 7h at a rate of 25ml/h and for more than 5h at a rate of 2000ml/h Third: External DC 15V power supply |
Drug Library | Up to 1000 drugs are provided |
Dimensions | 300 mm (L) x 180mm (W) x 90mm(H) |